Specifications

EBC Amperage
Channels Icon
0.5 mA - 6A
Selectable
EBC Range
Resolution Icon
0 - 20 Ω
EBC Accuracy
Recording Rate Icon
0.1 Ω
EBC Voltage
Explosive Samples Icon
Up to 40 V
Sensors
Maximum Blastholes Icon
7
Sampling Rate
Battery Life Icon
1 MHz
DataTrap II™ Schematics
Power supply:
115/230 V (Selectable)

Inputs:
Piezoelectric sensor (possible adjusting of the sensitivity), photo–sensor, wire–burst (start and stop), optical fibers (with transducers)

Outputs for oscilloscope:
Firing impusle signal, Signal from piezo–sensor (amplified), Signal from photo–sensor (forwarded)

FIRING IMPULSE

Amperage:
500 mA — 6 A (adjustable)

Accuracy:
Better than 1%

Duration:
0.5 — 20 ms (adjustable)

Voltage:
Up to 45 V

OHMMETER

Measuring range:
0.0 — 19.99 Ω

Measuring accuracy:
0.1 Ω

Functions:
Zeroing, resetting

Display:
Monochromatic, 4 x 20 characters

PC interface:
RS232, DB9 female connector

Warranty:
MREL’s 1 year Comprehensive Parts and Labour Warranty.

Technical Support:
MREL’s Unlimited Technical Support Program by secure customer portal, email, and telephone.
Expand See More
Collapee See Less
Upgrades Icon

Upgrades

TimeTrap™ Delay Time Recorder - Full Edition:
This upgrade will allow for the measurement of the following:

Delay Time:
- Nonelectric Detonators
- Impact Fuses
- Trunkline Delay Unit (Bunch Block)
- Relay Element

Velocity:
- Shocktube Velocity
- Detonating Cord Velocity

Sampling Rate Upgrade:
This upgrade will allow upgrade the unit from one microsecond per sample to 100 nanoseconds per sample.